top of page

Heating & Cooling Circulator

-120℃~300℃

未标题-1.png

HR Series

  • Provides both high and low temperature environments,

  • Fully sealed pipeline design,

  • Rapid heating and cooling,

  • Safe and durable

Overview

HR series a kind of heating & cooling circulator device that can provide heating source or cold source. It usually consists of a main control system and two independent temperature control systems, respectively used to control the temperature of high and low temperature areas. It’s widely used in scientific research laboratories, industrial production, pharmaceutical manufacturing, and other fields. It can provide a high-temperature environment for baking, heat treatment, drying and other operations, as well as a low-temperature environment for freezing, cooling, refrigeration and other applications.The fully enclosed pipeline design and high-efficiency plate heat exchange,while reducing the demand for heat transfer fluid and improve the heat utilization rate cf the system.While reducing the demand for thermal fluid,improve the heat utilization rate of the system to achieve rapid temperature rise and fall.The heat transfer medium is in a closed system with an expansion vessel,and the heat transfer medium in the expansion vessel does not participate in the circulation,whether it is high temperature or low temperature.The temperature of the expansion tank keep at 60℃ which effectively reduces the risk of moisture absorption and volatilization of the heat transfer medium during the operation.

Features 

  • Pre-cooling device,refrigeration system and heating system can be used together

  • It can be used together with 20L,50L,100L and other reaction togetherThe material inthe reactor can be cooled to -25℃,or heated to 200℃Refrigeration system compressor,oil separator,solenoid valve,expansion valve,All with importedbrandsCool down fast,and can force rapid cooling

  • With high and low voltage protection,overloadprotection,overcurent protection,connection.Ground protectionand other protection functionsThe evaporator with a fully brazed plate heat exchanger

  • Th eliquid level tube monitors the energy in real time to avoid the lack of heat transfer fluid

  • The closed circulator system,reduce the volatilization of the refrigerant and protect the health of the experimenterThe liquid storage tank and circulation pipeline made of 304 stainless steel,with good corrosion resistance

  • The shell with electrostatic plastic spray SPCC,with good anti-corrosion effectWith stable and reliable function,Long-term continuous operation

Typical Applications

It’s widely used in scientific research laboratories, industrial production, pharmaceutical manufacturing, and other fields. It can provide a high-temperature environment for baking, heat treatment, drying and other operations, as well as a low-temperature environment for freezing, cooling, refrigeration and other applications.

2.png
3.png
1.png

Model Selection Guide

Step 1

Provide working condition: Industry, support equipment type

Step 3

Working temperature range

Step 2

Supporting equipment model and size

Step 4

Select the model

4.png

Customization Service

Explosion-proof, water-cooled or air-cooled can be customized according to customer's working conditions PLC control: including Siemens S7-200smart PLC control system, material temperature and equipment outlet temperature can be switched freely

5.png

High Efficiency Plate
Heat Exchanger

未标题-1.png
未标题-1.png

No oil change required.While reducing the demand for thermal fluid, improve the heat utilization rate of the system and achieve rapid temperature rise and fall. The circulation system of the heat carrier fluid is provided with an exhaust port, which can complete the filling of the heat transfer fluid

Product Detail

1.png

Circulation Pump

Using magnetic pump, no mechanical shaft seal, solve the problem of circulating pump leakage

2.png

Compressor

Use brand compressors, such as Tecumseh/Danfoss/Copeland, etc., with low noise and stable operation

3.png

Danfoss Expansion Valve

Real-time control of the flow of the refrigerant to create conditions for the evaporation of the refrigerant under the condition of high temperature and high pressure

4.png

Copper Brazed Plate Heat Exchanger

The copper brazed plate heat exchanger is used to improve the heat exchange efficiency per unit area and reduce the usage of heat transfer medium

5.png

Safety Protection

Various safety protection measures such as leakage protection, overcurrent and thermal protection, phase loss protection, etc

Model
HR-70B
HR-100B
HR-150B
640*530*1400
640*530*1400
710*610*1400
970*800*1350
170
170
220
245
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
35
35
42
70
20
20
28
12
G3/4" outer thread
G3/4" outer thread
G3/4" outer thread
G1" outer thread
17
17
35
50
air cooling
air cooling
Sealed air cooling
Sealed air cooling
PT100
PT100
PT100
PT100
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
1800
1800
2100
2800
8600
8600
11000
12000
11500
11500
15750
18000
6(7)
6(7)
9(10)
15
12
12
15
23
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
-25~200℃;±1℃
-25~200℃;±1℃
-25~200℃;±1℃
-25~200℃;±1℃
Model
HR-70N
HR-100N
HR-150N
640*530*1400
640*530*1400
710*610*1400
970*800*1350
170
170
220
340
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
35
35
42
42
20
20
28
28
G3/4" outer thread
G3/4" outer thread
G3/4" outer thread
G1" outer thread
17
17
35
100
Sealed air cooling
Sealed air cooling
Sealed air cooling
Sealed air cooling
PT100
PT100
PT100
PT100
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
750
750
900
1100
10500
10500
11000
12000
12775
12775
15750
18000
6(7)
6(7)
9(10)
15
12
12
15
23
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
-40~200℃;±1℃
-40~200℃;±1℃
-40~200℃;±1℃
-40~200℃;±1℃
Model
HR-50T
HR-70T
HR-100T
HR-150T
810*710*1240
810*710*1240
970*800*1250
970*800*1350
1200*850*1350
210
210
280
290
370
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Material temperature and equipment outlet temperature can be switched automatically.
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
25
25
35
35
35
6
6
12
12
12
DN20
DN20
DN20
DN20
DN20
10
10
17
35
35
Sealed air cooling
Sealed air cooling
Sealed air cooling
Sealed air cooling
Sealed air cooling
PT100
PT100
PT100
PT100
PT100
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
Overvoltage, delay, overcurrent, overheating, leakage, protector
4800
4800
8550
11150
15150
7900
7900
14800
16500
18500
9000
9000
15750
18375
22375
4.5
4.5
6
9
9
11
11
17
20
20
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
380(220/480)50Hz 3P
-80~200℃;±1℃
-80~200℃;±1℃
-80~200℃;±1℃
-80~200℃;±1℃
-80~200℃;±1℃

Get an Instant Quote

Thanks!