top of page

UC Series

Heating Circulator

RT~300℃

  • UC-RT~200℃ Series 

  • UC-RT~300℃ Series

  • Oil electric heating system with a totally enclosed structure,PID intelligent temperature control

未标题-1.png

Overview

The UC High Temperature Circulator is a type of closed high-temperature circulator, which adopts electric heating method and outputs heat transfer fluid to heat the materials in the matching reaction vessel through the circulating pump. It is widely used in pharmaceutical and chemical industries and reactor assembly units requiring high-temperature conditions

Features

  • Equipped with exhaust valve, which can immediately discharge the gas overflowed due to the rise in system medium temperature;

  • Equipped with over-temperature alarm function, overload protection, and over-current protection function;

  • Temperature control adopts PID method, with high temperature control accuracy;

  • Adopting a fully closed-loop circulation system to extend the service life of the heat transfer fluid;

  • For Class IIB explosive environments, the equipment can use explosion-proof products of EXdIIBT4/EXdII CT4 grade.

  • Inject cooling water to adjust the temperature of the heat transfer fluid quickly to meet the requirements of the process conditions;

  • The circulation system adopts stainless steel material, corrosion-resistant, pollution-resistant, and prolonged operating cycle;

  • The system temperature control can be heated from room temperature to 300℃

Typical Applications

High-temperature circulators are widely used in chemical synthesis, petrochemicals, life sciences, pharmaceutical manufacturing, and energy industries, for drug synthesis, distillation separation, emulsification, drying, constant temperature reaction, solution heating and insulation, and other operations. The high-temperature circulator can control the medium temperature with high precision, reliability, and sensitivity, adjust the heating power, separate and collect products to meet various experimental and production needs.

YUC系列高温循环器-英文_02.png
1.png

Side inlet, side exhaust, rounded corner design, install casters, more convenient to move.

2.png

Level visualization.

4.png

Explosion proof and water cooling(Optional).

3.png

Touch button, easy operation. with drain port for easy discharge of waste liquid.

5.png

Equipped with an exhaust valve, which can eliminate the cause in time.Gas escaping when the system medium heats up.

UC-RT~200℃
UC-3020
UC-5020
UC-10020
UC-15020
UC-25020
UC-38020
UC-600020
Temperature range(℃)
RT~200;±0.5
RT~200;±0.5
RT~200;±0.5
RT~200;±0.5
RT~200;±0.5
RT~200;±1
RT~200;±1
Temperature (℃)
5~30
5~30
5~30
5~30
5~30
5~30
5~30
Optimum Ambient Humidity(RH)
45~80%
45~80%
45~80%
45~80%
45~80%
45~80%
45~80%
Voltage(V)
220V/50/60Hz,1P
220V/50/60Hz,1P (Optional220V3P/380V3P)
380V/50/60Hz,3P(Optional220V 3P / 480V 3P)
380V/50/60Hz,3P(Optional220V 3P / 480V 3P)
380V/50/60Hz,3P(Optional220V 3P / 480V 3P)
380V/50/60Hz,3P(Optional220V 3P / 480V 3P)
380V/50/60Hz,3P(Optional220V 3P / 480V 3P)
Total power(kW)
3.2
5.2
10.4
15.4
25.5
39.5
62
Heating method
Electric heating
Electric heating
Electric heating
Electric heating
Electric heating
Electric heating
Electric heating
Temperature sensor
PT100
PT100
PT100
PT100
PT100
PT100
PT100
Cooling method
Water cooling
Water cooling
Water cooling
Water cooling
Water cooling
Water cooling
Water cooling
Safety protection
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Heating power(kW)
3
5
10
15
25
38
60
The rated flow rate (L/min)
20
20
42
42
125
200
315
Loop interface
DN15(OT)
DN15(OT)
DN20(OT)
DN20(OT)
DN25(FI)
DN25(FI)
DN32(FI)
Cooling water interface
DN15
DN15
DN20
DN20
DN25
DN25
DN32
Control system
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Program programming
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Control model
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Protocol
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
Operation panel
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
Data export
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Weight(Kg)
68
78
88
100
130
170
285
Packing size(mm)
470*400*810
470*400*810
700*570*810
750*620*1000
800*680*1170
1000*800*1210
1200*900*1610
UC-RT~300℃
UC-3030
UC-5030
UC-10030
UC-15030
Temperature range(℃)
RT~300;±0.5
RT~300;±0.5
RT~300;±0.5
RT~300;±0.5
Temperature (℃)
5~30
5~30
5~30
5~30
Optimum Ambient Humidity(RH)
45~80%
45~80%
45~80%
45~80%
Voltage(V)
220V/50/60Hz,1P
380V/50/60Hz,3P (Optional 220V3P/380V3P)
380V/50/60Hz,3P(Optional220V3P/480V3P)
380V/50/60Hz,3P(Optional220V3P/480V3P)
Total power(kW)
4.2
6.2
11.5
15.9
Heating method
Electric heating
Electric heating
Electric heating
Electric heating
Temperature sensor
PT100
PT100
PT100
PT100
Cooling method
Water cooling
Water cooling
Water cooling
Water cooling
Safety protection
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Self-diagnosis; high pressure switch, overload relay, thermal protection device
Heating power(kW)
3
5.5
10
15
The rated flow rate (L/min)
15
35
50
50
Loop interface
DN-20 PN-10(FI)
DN-20 PN-10(FI)
DN-20 PN-10(FI)
DN25
Cooling water interface
DN15
DN15
DN20
DN20
Control system
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Siemens S7-200smartPLC
Program programming
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Addressable 5 programs with up to 40 steps each
Control model
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Material temperature and equipment outlet temperature can be switched automatically
Protocol
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
RS485 interface of modbus RTU protocol (optional RS232 Ethernet)
Operation panel
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
7-inch Siemens color touch screen (10-inch optional)
Data export
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Support U disk datas output, can be outputed temperature datas in TXT format
Weight(Kg)
85
95
105
115
Packing size(mm)
470*400*800
470*400*800
700*570*800
750*620*1050

Get an Instant Quote

Thanks!